Test fixture for SMD/chip components

The GW INSTEK LCR-15A is a test fixture for measuring chip/SMD components, specified for DC to 30 MHz. The product is stated by the manufacturer as an accessory compatible with the LCR-8200 series and comes with a STD-LOAD kit for high-frequency measurement calibration.

Function and construction

The LCR-15A provides a two-terminal DUT connection and is mounted on the measuring instrument via four BNC terminals with fastening handles. The test fixture has adjustable HIGH and LOW test pins, a test stage for placing the component, and an L-shaped bracket that can be mounted for increased stability. The STD-LOAD (specified as 100 Ω) is supplied as part of the kit for HF LOAD calibration at frequencies above 3 MHz.

Measurement procedure and calibration

This test fixture is designed to be used with the instrument's CORRECTION or FIXTURE COMPENSATION function. The manufacturer's guide describes step-by-step installation and recommended procedure for:

  • Attaching BNC terminals to the LCR instrument using fastening handles.
  • Adjusting the interval between LOW and HIGH test pins for correct DUT fit.
  • Performing OPEN, SHORT and HF LOAD corrections; HF LOAD calibration is recommended at measurement frequencies >3 MHz.
  • Placing the DUT vertically in the test stage and ensuring correct contact between test pins and component.

Documentation

The manufacturer's Quick Start Guide describes the installation, adjustment, and measurement procedure for the LCR-15A. For detailed information and further guidance, please refer to the manufacturer's manual:

See datasheet from the manufacturer

Typical applications

As indicated by the manufacturer, the LCR-15A is used for measuring chip-type components (SMD). It is intended for component sizes in the range 0201–1812 and components under 5 mm in width, and is used in conjunction with LCR meters where fixture compensation or correction is performed.

Specifications

  • Model: LCR-15A
  • Manufacturer: GW INSTEK
  • DUT Connector: 2-Terminal
  • Measurement Frequency: DC to 30 MHz
  • Maximum Voltage: ±45 V Peak (AC+DC)
  • Application Size: 0201 – 1812, <5 mm
  • Dimensions: 105 W x 47 H x 69 D mm
  • Weight: 185 g
  • Operating Environment: 0–50 °C, <70% RH
  • Included STD LOAD: Standard resistor (100 Ω)

The content is generated using AI – we reserve the right for errors.